How to Slove MB SD C4 Cannot Access OBD2 Port

​When using china clone mb sd connect compact 4 Multiplexer, it could not link to the car computer, MB SD Connect C4 offered a message, saying like “check cable connection / turn ignition on”. Then tried again, clone SD connect compact 4 multiplexer cannot access OBD2 port
2-1
According to customer’s feedback that he failed to access to the diagnostic OBD port when tried to use sd connect c4 read errors code from Benz SRS system. The system prompted an error message “check cable connection/turn ignition on”.
Possible Reason:

The error lies on the SD Connect C4’s battery.
​Solution from CnAutotool.com:

1) Check and record your MB SD Connect C4 multiplexer battery
2) Hook up a digital multimeter to set it to the direct current
3) Get two t-pins and plug them into the OBD socket at PIN 5 and PIN17 position
4) Put your positive lead to PIN16 and negative lead to PIN5.
5) Write down the voltage on the digital multimeter
6) Check if the voltage you from PIN16 and PIN 5 is same in step 1.
7) Find the light green wire with a blue tracer band of PIN10 of the OBDII connector.
8) If the voltage differs in step 1 and step 6, the problem is probably with your battery.
9) If the battery is damaged or broken, please replace your battery.

 

MB SD C4 Star Diagnostic Tool With Vediamo V05.01.01 Development and Engineering Software Plus EVG7 Tablet PC

Best Quality V2020.09 MB SD Connect Compact C4 Star Diagnostic TooL With Vediamo and DTS Engineering Software

Be the first to comment