MB SD C4 with EVG7 manual incl. FAQ , setup etc

Tips & Warning: Chrysler Diagnostics & Programming by MicroPod 2
What you can read in this post:

1.Solution to EVG7 Blue Screen working with SD Connect C4

2.Battery and hard disk disassembly and installation

3.Find out and use the on-screen keyboard.

4.The method to use EVG7 U disk.

Here we go one by one

Part 1: Solution to EVG7 Blue Screen working with SD Connect C4

Look this image of EVG7 Blue Screen:

MB SD C4 with EVG7 manual incl. FAQ , setup etc1

Solution:

1.Press the “On” button to turn on machine. Then press “SAS” button to enter bios settings.
MB SD C4 with EVG7 manual incl. FAQ , setup etc2

2.Change Sata startup mode.

MB SD C4 with EVG7 manual incl. FAQ , setup etc3

3.IDE: for Windows XP

AHCHI: for WIN7, 8 etc.
MB SD C4 with EVG7 manual incl. FAQ , setup etc4

4.Use the shift key to save and exit.

Restart the EVG7 and the Blue screen will disappear.

MB SD C4 with EVG7 manual incl. FAQ , setup etc5

Part 2: Battery and hard disk disassembly and installation

This upper left corner is the position of battery, the lower right corner is the position of the hard disk. Before

installing, please remove all the screws on the back cover.

MB SD C4 with EVG7 manual incl. FAQ , setup etc6

1.Hard disk disassembly and installation

Open the cover of hard disk.

MB SD C4 with EVG7 manual incl. FAQ , setup etc7

Remove the hard drive bay

MB SD C4 with EVG7 manual incl. FAQ , setup etc8

Take out the hard disk and the bay.

MB SD C4 with EVG7 manual incl. FAQ , setup etc9

Remove the hard drive connection cable

MB SD C4 with EVG7 manual incl. FAQ , setup etc10

Done.

Now you know how to install back, right?

MB SD C4 with EVG7 manual incl. FAQ , setup etc11

2.Battery disassembly and installation.

Disassembly:

Open the cover of the battery.

Take out the battery.

Installation:

Put back the battery and close the cover.

MB SD C4 with EVG7 manual incl. FAQ , setup etc12
MB SD C4 with EVG7 manual incl. FAQ , setup etc113
Part 3: Find out and use the on-screen keyboard.

Start – Programs – Accessories – Accessibility -On-screen keyboard.
MB SD C4 with EVG7 manual incl. FAQ , setup etc14
MB SD C4 with EVG7 manual incl. FAQ , setup etc15

Part 4: The method to use EVG7 U disk.

MB SD C4 with EVG7 manual incl. FAQ , setup etc16MB SD C4 with EVG7 manual incl. FAQ , setup etc18
MB SD C4 with EVG7 manual incl. FAQ , setup etc17

Remarks: There are stylus installation drivers and EVG7 hardware drivers in the mobile U disk. The drivers need to be installed manually

How-to Setup a MicroPod II for wiTECH 2

DESCRIPTION

If your dealership purchased a new microPOD and you would like to convert your existing microPOD for using with wiTECH 2.0 System, you need to download and install the microPOD Setup Utility to configure/setup your microPOD for Chrysler wiTech MicroPod 2.

For a video version of setting up a microPod 2 for wiTECH 2.0, please watch How To Set Up A New Device With wiTECH 2 (Note. You will have to be Logged into wiTECH 2.0 to view video)

NOTE: microPODs with a serial number beginning with “WFP” should NOT be used with this utility.

PROCEDURE

If you have a restricted network, you must first make sure that all sites listed below are enabled to be able to successfully use microPOD Setup Utility and the wiTECH 2.0 System.

1.mixpanel.com
2.bugsnag.com
3.fcawitech.com
4.chrysler.com
5.dealerconnect.com
6.jeep.com
7.witechsystem.com

Note: Please disable any Anti-Virus software that you have on your computer in order to allow the microPOD Setup Utility to install and run properly.

Steps to download and install the microPOD Setup Utility

IMPORTANT: Once the microPOD is configured using the microPOD Setup Utility, all the microPOD Wireless Settings will be deleted. You will be required to follow the instructions from the KB link titled “How to configure a Wireless Profile on a microPOD II”.

To download the application, please login to DealerCONNECT > Service > wiTECH Information > microPod Setup Utility

Step 1

Click on “Run” to begin the downloading process of microPOD Setup Utility.

10-1

Step 2

The install wizard will appear to install the wiTECH Driver x64 onto your computer if your PC has not been installed with wiTECH 1.0 application.

If the PC has been installed with wiTECH 1.0 App, you will not see the screen below and proceed to Step 6. Otherwise, click “Next” to proceed.

10-2

Step 3

Read the License Agreement carefully, and accept the terms in the license agreement. Then, click “Next” to continue.

10-3

Step 4

You are now ready to start the actual installation of the driver. You now need to click on “Install” for it to start.

10-4

Step 5

This will now install the wiTECH Driver x64. Once complete, the program will automatically proceed to the next step.

10-5

Step 6

Once the installation has completed, click “Finish”. Proceed to the following section, “Using the microPOD Setup Utility”.

10-6

Using the microPOD Setup Utility

NOTE: Please make sure that your computer is connected to the internet and the microPOD is connected to the computer via USB before starting this process. This application will help you configure your microPOD for wiTECH 2.0.

Step 1
Start microPOD Setup Utility by clicking the icon on the desktop:

10-07

If the microPOD Setup Utility that is installed is out of date, you will be forced to update to the newer version of the application.

10-7

Step 2

Please make sure your microPOD is connected to the PC via USB.

10-8

Step 2a

If you see the following screen you may not be connected to the internet, or have a firewall that blocks 1 or more of these websites.

10-9

Select “Continue” on the next screen for wiTECH 2.0 Device Setup and Configuration.

10-10

NOTE: If you only want to configure the wireless setting on a microPod device to use with wiTECH 2.0, click “Wireless Configuration” and follow instructions.

10-11

Select “Continue” on the next screen to begin attempting to connect to the microPOD device.

Step 3

Once your microPOD II is recognized by the utility, select “Continue” to proceed with the configuration.

10-12

NOTE: microPODs with a serial number beginning with “WFP” should NOT be used with this utility.

Step 4

If the utility does not find the microPOD device, please assure that the microPOD is connected via USB and click “Refresh”.

10-13

Step 5

The following screen will appear for up to 15 minutes while the microPOD device is being configured.

10-14

Step 6

The following screen will appear when the utility completed the configuration of microPOD for wiTECH 2.0 Application.

Note: After microPOD Setup Utility is ran, all existing wireless networks will be removed from the microPOD.

Important! Leave the microPod Setup Utility window running as you will be required to complete software updates to the microPod device before configuring the wireless.

Step 6a

Login into wiTECH 2.0 at https://login.n.fcawitech.com . The microPOD II that was just configured using the microPOD Setup Utility should appear in the  car diagnostic scanner wiTECH 2.0 discovery . You will need to update the operating system of your microPOD II before it can be used with wiTECH 2.0. Click “Continue”, and your web browser will redirect you to the page to download and install the operating system update as seen in the following step.

10-15

*NOTE: If microPOD II does not show up in discovery after a couple of minutes please power cycle your microPOD II by unplugging it and plugging it back in.

Step 7

Click “Update Now” and your microPOD II should continue to the update screen. Once updating, do not interrupt your microPOD II at any point until the update is complete.

10-16

*NOTE: This can take upwards of 9 minutes. It is normal activity for the microPOD II to reboot.

10-17

Step 8

Click “OK” and you will be navigated back to the wiTECH 2.0 discovery page. Your microPOD II should appear updated and ready for use.

10-18

Step 9

With the microPod Setup Utility still running, please follow the KB link listed below to configure wireless on the microPod device.

wiTECH Application does not prompt for update

wiTECH Application does not prompt for update and user sees “There are no application updates available this time” when checking for updates

DESCRIPTION

Due to some reasons, microPOD II may not notify the user of application updates. To troubleshoot this issue further, please follow the steps described below:

1.    Close the wiTECH Diagnostic Application and quit the wiTECH server by right-clicking on the green wiTECH Server in the System tray and selecting Quit.

5-1

2.    Restart wiTECH Server from All Programs -> wiTECH -> wiTECH Server
5-2

3.    Launch wiTECH Diagnostic Application.

4.    Select a VCI device and login to DealerCONNECT.

5.    Select Help > Check for Updates > Software Manager should launch and the user should be able to update.

6.    If you still do not see the prompt for application update, please contact your dealership IT/Network administrator to ensure that the network has access to CnAutotool.com and all sub-domains as trusted sites for checking and downloading the application updates.